Synopsis

Correcting Hardware Bias in Molecular Spectrometers

Physics 12, s85
More accurate measurements of CO2 in the atmosphere can be obtained by accounting for discrepancies in spectroscopy hardware.
A. Fleisher/NIST

Infrared spectroscopy is an irreplaceable tool for quantifying atmospheric CO2, but obtaining the gas concentration from a spectral signal depends on knowing the absorption cross section—how strongly the molecule interacts with photons at a particular wavelength. Researchers have long sought to determine the CO2 cross section for infrared wavelengths with a precision better than 0.1%, but even calculations from first principles come with an uncertainty above 1%. Now, by measuring a reference sample—whose composition was precisely known —with multiple highly sensitive cavity ring-down spectrometers (CRDSs), Adam Fleisher and colleagues at the National Institute of Standards and Technology in Maryland, have derived the CO2 cross section with an uncertainty of 0.06%.

In a CRDS, a laser beam bounces between a pair of mirrors and is gradually absorbed by the gas in the cavity, with the rate depending on the gas concentration. After minimizing known sources of error in a set of exquisitely precise CRDSs, Fleisher and colleagues were able to focus on the performance of the digitizer hardware—the part of the instrument that turns the analog output from the photodetector into a digital signal for analysis. When they compared the results of five separate digitizers, the researchers found unexpected biases unique to each device. By adjusting their measurements based on this previously uncharacterized digitizer bias, the team obtained a value for the absorption cross section with a 25-fold improvement in uncertainty relative to earlier results.

The improvement equates to a CO2 measurement precision of better than 0.4 parts per million at current atmospheric concentrations, which will allow more accurate characterization of gas sources and sinks. The result also applies to studies of other gas molecules, including the optical detection of biosignatures on exoplanets.

This research is published in Physical Review Letters.

–Marric Stephens

Marric Stephens is a freelance science writer based in Bristol, UK.


Subject Areas

Atomic and Molecular PhysicsElectronicsGeophysics

Related Articles

Seeing Collisions in Cold Molecular Clouds
Atomic and Molecular Physics

Seeing Collisions in Cold Molecular Clouds

Dense ensembles of laser-cooled molecules allow the observation of molecular collisions—a result that could lead to applications of cold molecular gases in quantum simulation and fundamental physics tests. Read More »

Probing Liquid Water’s Structure with Attosecond X-Ray Pulses
Condensed Matter Physics

Probing Liquid Water’s Structure with Attosecond X-Ray Pulses

Using an ultrafast technique, researchers shed light on how the hydrogen-bonded structure of water is reflected in its x-ray spectrum. Read More »

Precise Measurement of Hydrogen’s Energy Levels
Atomic and Molecular Physics

Precise Measurement of Hydrogen’s Energy Levels

Researchers have measured the transition energy of several highly excited states, which could help resolve a discrepancy about the size of the proton. Read More »

More Articles