Magnetically insulated transmission lines (MITLs), which could transfer power density up to , are one of the most important technologies in pulsed power. In pulsed power systems for the -pinch fusion or radiography, a long MITL acts as a transmission line as well as a spatial isolation between load and driver. The length of MITLs in such systems will be up to a few, even tens of meters. However, the anode and cathode (A-K) gap is only a few centimeters to make the centering of the MITL’s electrodes be one of the most challenging issues. Cathodes of long coaxial MITLs, such as that of Hermes-III and RITS, are fixed at the low voltage end while keeping the other end free of support. However, such a method will be very difficult for longer MITLs due to gravity and engineering reasons. An interesting question for such MITL design is to find a way to position the electrodes to the ideal position while hardly damaging the power flow. It is also a very practical concern in the construction of large pulsed-power facilities. In this paper, a high inductive helical supported MITL in a 10-stage linear transformer driver system is investigated. Both experiments and particle-in-cell simulations show that magnetic insulation is well established and power flow could be transmitted to load efficiently.
9 More- Received 19 October 2011
DOI:https://doi.org/10.1103/PhysRevSTAB.15.110401
This article is available under the terms of the Creative Commons Attribution 3.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI.
Published by the American Physical Society