Abstract
We report the results of a weakly interacting massive particle (WIMP) dark matter search using the full 80.1 live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6%. With a fiducial liquid xenon target mass of 54.0 kg, no significant excess events were found above the expected background. A profile likelihood ratio analysis confirms our earlier finding that the PandaX-I data disfavor all positive low-mass WIMP signals reported in the literature under standard assumptions. A stringent bound on a low-mass WIMP is set at a WIMP mass below , demonstrating that liquid xenon detectors can be competitive for low-mass WIMP searches.
7 More- Received 10 May 2015
DOI:https://doi.org/10.1103/PhysRevD.92.052004
© 2015 American Physical Society