Practical speed meter designs for quantum nondemolition gravitational-wave interferometers

Patricia Purdue and Yanbei Chen
Phys. Rev. D 66, 122004 – Published 27 December 2002
PDFExport Citation

Abstract

In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors (e.g., LIGO-III and EURO), one strategy is to monitor the relative momentum or speed of the test-mass mirrors, rather than monitoring their relative position. A previous paper analyzed a straightforward but impractical design for a speed-meter interferometer that accomplishes this. This paper describes some practical variants of speed-meter interferometers. Like the original interferometric speed meter, these designs in principle can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies. These variants essentially consist of a Michelson interferometer plus an extra “sloshing” cavity that sends the signal back into the interferometer with opposite phase shift, thereby cancelling the position information and leaving a net phase shift proportional to the relative velocity. In practice, the sensitivity of these variants will be limited by the maximum light power Wcirc circulating in the arm cavities that the mirrors can support and by the leakage of vacuum into the optical train at dissipation points. In the absence of dissipation and with squeezed vacuum (power squeeze factor e2R0.1) inserted into the output port so as to keep the circulating power down, the SQL can be beat by h/hSQLWcircSQLe2R/Wcirc at all frequencies below some chosen fopt100Hz. Here WcircSQL800kW(fopt/100Hz)3 is the power required to reach the SQL in the absence of squeezing. (However, as the power increases in this expression, the speed meter becomes more narrow band; additional power and reoptimization of some parameters are required to maintain the wide band. See Sec. III B.) Estimates are given of the amount by which vacuum leakage at dissipation points will debilitate this sensitivity (see Fig. 12); these losses are 10% or less over most of the frequency range of interest (f10Hz). The sensitivity can be improved, particularly at high freqencies, by using frequency-dependent homodyne detection, which unfortunately requires two 4-km-long filter cavities (see Fig. 4).

  • Received 27 July 2002

DOI:https://doi.org/10.1103/PhysRevD.66.122004

©2002 American Physical Society

Authors & Affiliations

Patricia Purdue and Yanbei Chen

  • Theoretical Astrophysics, California Institute of Technology, Pasadena, California 91125

References (Subscription Required)

Click to Expand
Issue

Vol. 66, Iss. 12 — 15 December 2002

Reuse & Permissions
Access Options
Author publication services for translation and copyediting assistance advertisement

Authorization Required


×
×

Images

×

Sign up to receive regular email alerts from Physical Review D

Log In

Cancel
×

Search


Article Lookup

Paste a citation or DOI

Enter a citation
×