Abstract
A new precision half-life measurement of was conducted using the TwinSol -counting station at the University of Notre Dame. The new measured value of s is in good agreement with the most recent measurement, while being 3 times more precise. Using these new measurements, an evaluation of the half-life has been performed, leading to an average half-life of s, which is 5 times more precise than it's predecessor and has a more satisfactory Birge ratio of 1.1. To aid in future measurements of correlation parameters, a new Fermi to Gamow-Teller mixing ratio and correlation parameters for this mixed transition have been calculated assuming the standard model validity using the new world half-life.
- Received 20 March 2017
DOI:https://doi.org/10.1103/PhysRevC.96.015502