Demonstration of the Casimir Force in the 0.6 to 6μm Range

S. K. Lamoreaux
Phys. Rev. Lett. 78, 5 – Published 6 January 1997; Erratum Phys. Rev. Lett. 81, 5475 (1998)
PDFExport Citation

Abstract

The vacuum stress between closely spaced conducting surfaces, due to the modification of the zero-point fluctuations of the electromagnetic field, has been conclusively demonstrated. The measurement employed an electromechanical system based on a torsion pendulum. Agreement with theory at the level of 5% is obtained.

  • Received 28 August 1996

DOI:https://doi.org/10.1103/PhysRevLett.78.5

©1997 American Physical Society

Erratum

Authors & Affiliations

S. K. Lamoreaux

  • Physics Department, University of Washington, Box 35160, Seattle, Washington 98195-1560

Comments & Replies

Comment on “Demonstration of the Casimir Force in the 0.6 to 6 μm Range”

Astrid Lambrecht and Serge Reynaud
Phys. Rev. Lett. 84, 5672 (2000)

Lamoreaux Replies:

S. K. Lamoreaux
Phys. Rev. Lett. 84, 5673 (2000)

References (Subscription Required)