Atomic spectral line free parameter deconvolution procedure

V. Milosavljević and G. Poparić
Phys. Rev. E 63, 036404 – Published 27 February 2001
PDFExport Citation

Abstract

We report an advanced numerical procedure for deconvolution of theoretical asymmetric convolution integral of a Gaussian and a plasma broadened spectral line profile jA,R(λ) for spectal lines. Our method determines all broadening parameters, self-consistently and directly from the line profile with minimal assumptions or prior knowledge. This method is useful for obtaining complete information on all plasma parameters directly from the recorded shape of a single line, which is very important in case no other diagnostic methods are available. The method is also convenient for determination of plasma parameters in the case of a symmetrical profile such as Voigt one.

  • Received 15 May 2000

DOI:https://doi.org/10.1103/PhysRevE.63.036404

©2001 American Physical Society

Authors & Affiliations

V. Milosavljević and G. Poparić

  • Faculty of Physics, University of Belgrade, Studenski trg 16, P.O. Box 368, 11001 Belgrade, Yugoslavia

Comments & Replies

Comment on “Atomic spectral line-free parameter deconvolution procedure”

D. Nikolić, S. Djurović, Z. Mijatović, and R. Kobilarov
Phys. Rev. E 67, 058401 (2003)

References (Subscription Required)

Click to Expand
Issue

Vol. 63, Iss. 3 — March 2001

Reuse & Permissions
Access Options
Author publication services for translation and copyediting assistance advertisement