Observing binary inspiral in gravitational radiation: One interferometer

Lee Samuel Finn and David F. Chernoff
Phys. Rev. D 47, 2198 – Published 15 March 1993
PDFExport Citation

Abstract

Close binary systems of compact objects with less than ten minutes remaining before coalescence are readily identifiable sources of gravitational radiation for the United States Laser Interferometer Gravitational-Wave Observatory (LIGO) and the French-Italian VIRGO gravitational-wave observatory. As a start toward assessing the full capabilities of the LIGO-VIRGO detector network, we investigate the sensitivity of individual LIGO-VIRGO-like interferometers and the precision with which they can determine the characteristics of an inspiralling binary system. Since the two interferometers of the LIGO detector share nearly the same orientation, their joint sensitivity is similar to that of a single, more sensitive interferometer. We express our results for a single interferometer of both initial and advanced LIGO design, and also for the LIGO detector in the limit that its two interferometers share exactly the same orientation. We approximate the secular evolution of a binary system as driven exclusively by its leading-order quadrupole gravitational radiation. Observations of a binary in a single interferometer are described by four characteristic quantities: an amplitude A, a chirp mass M, a time T, and a phase ψ. We find the amplitude signal-to-noise ratio (SNR) ρ of an observed binary system as a function of A and M for a particular orientation of the binary with respect to the interferometer, and also the distribution of SNR's for randomly oriented binaries at a constant distance. To assess the interferometer sensitivity, we calculate the rate at which sources are expected to be observed and the range to which they are observable. Assuming a conservative rate density for coalescing neutron-star binary systems of 8×108 yr1 Mpc3, we find that the advanced LIGO detector will observe approximately 69 yr1 with an amplitude SNR greater than 8. Of these, approximately 7 yr1 will be from binaries at distances greater than 950 Mpc. We give analytic and numerical results for the precision with which each of the characteristic quantities can be determined by interferometer observations. For neutron-star binaries, the fractional 1σ statistical error in the determination of A is equal to 1ρ. For ρ>8, the fractional 1σ error in the measurement of M in the advanced LIGO detectors is less than 2×105, a phenomenal precision. The characteristic time is related to the moment when coalescence occurs, and can be measured in the advanced detectors with a 1σ uncertainty of less than 3×104 s (assuming ρ>8). We also explore the sensitivity of these results to a tunable parameter in the interferometer design (the recycling frequency). The optimum choice of the parameter is dependent on the goal of the observations, e.g., maximizing the rate of detections or maximizing the precision of measurement. We determine the optimum parameter values for these two cases. The calculations leading to the SNR and the precision of measurement assume that the interferometer observations extend over only the last several minutes of binary inspiral, during which time the orbital frequency increases from approximately 5 Hz to 500 Hz. We examine the sensitivity of our results to the elapsed time of the observation and show that observations of longer duration lead to very little improvement in the SNR or the precision of measurement.

  • Received 18 November 1992

DOI:https://doi.org/10.1103/PhysRevD.47.2198

©1993 American Physical Society

Authors & Affiliations

Lee Samuel Finn

  • Department of Physics and Astronomy, Northwestern University, Evanston, Illinois 60208

David F. Chernoff

  • Department of Astronomy, Cornell University, Ithaca, New York 14853

References (Subscription Required)

Click to Expand
Issue

Vol. 47, Iss. 6 — 15 March 1993

Reuse & Permissions
Access Options
Author publication services for translation and copyediting assistance advertisement

Authorization Required


×
×

Images

×

Sign up to receive regular email alerts from Physical Review D

Log In

Cancel
×

Search


Article Lookup

Paste a citation or DOI

Enter a citation
×